Files
rk-backend/data/mongoDb/rk.groups.json
T
2026-10-07 11:30:32 +02:00

1671 lines
33 KiB
JSON

[{
"_id": {
"$oid": "6996ec897d8011b2d05da552"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Aufgabe",
"type": "Behaelter",
"nr": "4210",
"funcTxt": "G_4210_Aufgabe",
"ort": "nicht zugewiesen",
"info": "Aufgabe Bunker mit Kippvorrichtung",
"options": {
"oldId": "1",
"oldAggTyp": "unbekannt"
},
"__v": 0,
"displayName": "Aufgabe Bunker"
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da558"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Band",
"type": "Band",
"nr": "2310",
"funcTxt": "G_2310_Band",
"ort": "nicht zugewiesen",
"info": "Plattenband Bandantrieb 4kW IE4 / Betriebsspannung 400V 50Hz",
"options": {
"fu": true,
"motor_anzahl": "1",
"oldId": "3",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da55b"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Haspel",
"type": "Haspel",
"nr": "2310",
"funcTxt": "G_23101_Haspel",
"ort": "nicht zugewiesen",
"info": "Haspelantrieb 11kW IE4 / Betriebsspannung 400V 50Hz",
"options": {
"rechtsLinks": true,
"oldId": "4",
"oldAggTyp": "Motor"
},
"__v": 0,
"displayName": ""
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da561"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Band",
"type": "Band",
"nr": "2311",
"funcTxt": "G_2311_Band",
"ort": "nicht zugewiesen",
"info": "Förderband 25.4m / 1000 / 18° 400V, 50Hz, IE4 mit Motorschutz TF-3 Kaltleiterfühler (ohne Auslösegerät) ",
"options": {
"oldId": "6",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da564"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Bandmagnet",
"type": "Band",
"nr": "2611",
"funcTxt": "G_2611_Bandmagnet",
"ort": "nicht zugewiesen",
"info": "SEW 400V, 50Hz Schätzung 2.2KW ",
"options": {
"oldId": "7",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da567"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Sieb",
"type": "Sieb",
"nr": "1211",
"funcTxt": "G_1211_Sieb",
"ort": "nicht zugewiesen",
"info": "Stangenschenrer 400V, 50Hz, 3x 2.5KW, Bremsgerät / IE4 ",
"options": {
"bremse": true,
"motor_anzahl": "2",
"oldId": "8",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da56a"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Band",
"type": "Band",
"nr": "2312",
"funcTxt": "G_2312_Band",
"ort": "nicht zugewiesen",
"info": "Förderband 8m / 1000 / 16° 400V, 50Hz, IE4, mit Motorsschutz TF-3 Kaltleiterfühler (ohne Auslösegerät) ",
"options": {
"oldId": "9",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da56d"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Brecher",
"type": "Brecher",
"nr": "1111",
"funcTxt": "G_1111_Brecher",
"ort": "nicht zugewiesen",
"info": "Brecher Riemenantrieb E-Motor IE4 / Drehzahlsensor ",
"options": {
"oldId": "10",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da570"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Band",
"type": "Band",
"nr": "2313",
"funcTxt": "G_2313_Band",
"ort": "nicht zugewiesen",
"info": "Förderband 25.5m/800/0°,12.0° (nicht reversierbar) 400V, 50Hz, IE4 mit Motorschutz TF-3 Kaltleiterfühler (ohne Auslösegerät) ",
"options": {
"oldId": "11",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da573"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Bandmagnet",
"type": "Band",
"nr": "2613",
"funcTxt": "G_2613_Bandmagnet",
"ort": "nicht zugewiesen",
"info": "SEW 400V, 50Hz Schätzung 2.2KW ",
"options": {
"oldId": "12",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da576"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Band",
"type": "Band",
"nr": "2314",
"funcTxt": "G_2314_Band",
"ort": "nicht zugewiesen",
"info": "Förderband 398.55m/650/1°,4.4°,0.0° 400V, 50Hz, IE4 mit Motorschutz TF-3 Kaltleiterfühler (ohne Auslösegerät) ",
"options": {
"softstarter": true,
"oldId": "20",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da579"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Weiche",
"type": "Weiche",
"nr": "2420",
"funcTxt": "G_2420_Weiche",
"ort": "nicht zugewiesen",
"info": "Wechselklappe Antrieb 0,12 kW / Typ CMEP-ELA-20 Ausführung ELA20,1-TR-V-400-1-0-3-0-2-0_1 / 2 Stück Positionsabgrenzung ",
"options": {
"rechtsLinks": true,
"oldId": "30",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da57c"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "TurboWasher",
"type": "Turbowasher",
"nr": "1321",
"funcTxt": "G_1321_TurboWasher",
"ort": "nicht zugewiesen",
"info": "TurboWasher 400V, 50Hz, Typ SEW K 167 17 U/Min mit eingebautem Thermoschutz ",
"options": {
"oldId": "31",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da57f"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Sieb",
"type": "Sieb",
"nr": "1221",
"funcTxt": "G_1221_Sieb",
"ort": "nicht zugewiesen",
"info": "Siebmaschine 1500UpM /Doppellagerung, IE4 ",
"options": {
"bremse": true,
"oldId": "32",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da582"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Gurtfoerderer",
"type": "Gurtfoerderer",
"nr": "2321",
"funcTxt": "G_2321_Gurtfoerderer",
"ort": "nicht zugewiesen",
"info": "Doppelgurtförderer 15.7/1000/0.0°/90° 400V, 50Hz, IE4, mit Motorschutz TF-3 Kaltleiterfühler (ohne Auslösegerät), FU Elektro-Lieferant, Fabrikat Siemens ",
"options": {
"fu": true,
"motor_anzahl": "2",
"oldId": "33",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da585"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Band",
"type": "Band",
"nr": "2322",
"funcTxt": "G_2322_Band",
"ort": "nicht zugewiesen",
"info": "Förderband 16.6m/650/15° 400V, 50Hz, IE4, mit Motorschutz TF-3 Kaltleiterfühler (ohne Auslösegerät) ",
"options": {
"oldId": "34",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da588"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Bandmagnet",
"type": "Band",
"nr": "2622",
"funcTxt": "G_2622_Bandmagnet",
"ort": "nicht zugewiesen",
"info": "Überbandmagnetschenrer SEW 400V, 50Hz Schätzung 2.2KW ",
"options": {
"oldId": "35",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da58b"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Sieb",
"type": "Sieb",
"nr": "1222",
"funcTxt": "G_1222_Sieb",
"ort": "nicht zugewiesen",
"info": "Siebmaschine 1500 UpM / Einfachlagerung / IE4 ",
"options": {
"bremse": true,
"oldId": "37",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da58e"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Setzmaschine",
"type": "Setzmaschine",
"nr": "1322",
"funcTxt": "G_1322_Setzmaschine",
"ort": "nicht zugewiesen",
"info": "Setzmaschine Typ GR-1400 x 2000 Nord 2 (Drehkolbenschieber)mit Steuerschrank(intern verdrahtet400V AC,3-phase) Installation der Komponenten durch Installateur ",
"options": {
"oldId": "38",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da594"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Sieb",
"type": "Sieb",
"nr": "1223",
"funcTxt": "G_1223_Sieb",
"ort": "nicht zugewiesen",
"info": "Siebmaschine 400 V, 50Hz., Richterreger Fa. Friedrich 1000UpM / IE4 ",
"options": {
"fu": true,
"oldId": "40",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da597"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Band",
"type": "Band",
"nr": "2323",
"funcTxt": "G_2323_Band",
"ort": "nicht zugewiesen",
"info": "Förderband 19m/650/14° 400V, 50Hz, IE4, mit Motorschutz TF-3 Kaltleiterfühler (ohne Auslösegerät) ",
"options": {
"oldId": "41",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da59a"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Setzmaschine",
"type": "Setzmaschine",
"nr": "1323",
"funcTxt": "G_1323_Setzmaschine",
"ort": "nicht zugewiesen",
"info": "Typ G-1700 x 2000 Nord 2 (Drehkolbenschieber)+1x4.0KW(Zellradschleuse) mit Steuerschrank(intern verdrahtet400V AC,3-phase) Installation der Komponenten durch Installateur ",
"options": {
"oldId": "42",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5a0"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Sieb",
"type": "Sieb",
"nr": "1224",
"funcTxt": "G_1224_Sieb",
"ort": "nicht zugewiesen",
"info": "SiebmaschineFabrikat Italvibras MVSI 10/6500-S02, 2 x 4.3 kW Vibrationsmotor ",
"options": {
"motor_anzahl": "2",
"oldId": "44",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5a3"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Sieb",
"type": "Sieb",
"nr": "1225",
"funcTxt": "G_1225_Sieb",
"ort": "nicht zugewiesen",
"info": "Siebmaschine 1500 UpM / Doppellagerung / IE4 ",
"options": {
"bremse": true,
"oldId": "45",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5a6"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Band",
"type": "Band",
"nr": "2327",
"funcTxt": "G_2327_Band",
"ort": "nicht zugewiesen",
"info": "Förderband 9/500/0° 400V, 50Hz, IE4, mit Motorschutz TF-3 Kaltleiterfühler (ohne Auslösegerät) ",
"options": {
"oldId": "46",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5a9"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Band",
"type": "Band",
"nr": "2324",
"funcTxt": "G_2324_Band",
"ort": "nicht zugewiesen",
"info": " Förderband reversierbar 2.7/500/0° 400V, 50Hz, IE4, mit Motorschutz TF-3 Kaltleiterfühler (ohne Auslösegerät) ",
"options": {
"rechtsLinks": true,
"oldId": "47",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5ac"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Band",
"type": "Band",
"nr": "2325",
"funcTxt": "G_2325_Band",
"ort": "nicht zugewiesen",
"info": "Förderband 27.9/650/0° 400V, 50Hz, IE4, mit TF-3 Kaltleiterfühler f. Wärmeklasse F (ohne Auslösegerät) ",
"options": {
"oldId": "48",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5af"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Band",
"type": "Band",
"nr": "2326",
"funcTxt": "G_2326_Band",
"ort": "nicht zugewiesen",
"info": "Förderband 5.0/500/0° 400V, 50Hz, IE4, mit Motorschutz TF-3 Kaltleiterfühler (ohne Auslösegerät) ",
"options": {
"oldId": "49",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5b2"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Weiche",
"type": "Weiche",
"nr": "2424_1",
"funcTxt": "G_2424_1_Weiche",
"ort": "nicht zugewiesen",
"info": "Wechselklappe (Schneckengetriebmotor) 230V/400 Dreieck/Stern, SEW Schneckengetriebemotor SH67/T DRN71M6 ",
"options": {
"rechtsLinks": true,
"oldId": "50",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5b5"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Weiche",
"type": "Weiche",
"nr": "2424_2",
"funcTxt": "G_2424_2_Weiche",
"ort": "nicht zugewiesen",
"info": "Wechselklappe (Schneckengetriebmotor) 230V/400 Dreieck/Stern, SEW Schneckengetriebemotor SH67/T DRN71M6 ",
"options": {
"rechtsLinks": true,
"oldId": "51",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5b8"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Weiche",
"type": "Weiche",
"nr": "2424_3",
"funcTxt": "G_2424_3_Weiche",
"ort": "nicht zugewiesen",
"info": "Wechselklappe (Schneckengetriebmotor) 230V/400 Dreieck/Stern, SEW Schneckengetriebemotor SH67/T DRN71M6 ",
"options": {
"rechtsLinks": true,
"oldId": "52",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5bb"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Weiche",
"type": "Weiche",
"nr": "2423",
"funcTxt": "G_2423_Weiche",
"ort": "nicht zugewiesen",
"info": "Wechselklappe (Schneckengetriebmotor) 230V/400 Dreieck/Stern, SEW Schneckengetriebemotor SH67/T DRN71M6 ",
"options": {
"rechtsLinks": true,
"oldId": "53",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5be"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Weiche",
"type": "Weiche",
"nr": "2422",
"funcTxt": "G_2422_Weiche",
"ort": "nicht zugewiesen",
"info": "Wechselklappe (Schneckengetriebmotor) 230V/400 Dreieck/Stern, SEW Schneckengetriebemotor SH67/T DRN71M6 ",
"options": {
"rechtsLinks": true,
"oldId": "54",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5c1"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Weiche",
"type": "Weiche",
"nr": "2421",
"funcTxt": "G_2421_Weiche",
"ort": "nicht zugewiesen",
"info": "Wechselklappe (Schneckengetriebmotor) Antrieb 0.12 kW / Typ CMEP-ELA-20 Auführung ELA20.1-TR-V-400-1-0-3-0-2-0_1 / 2 Stück Positiosabgrenzung ",
"options": {
"rechtsLinks": true,
"oldId": "55",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5c4"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Sieb",
"type": "Sieb",
"nr": "1226",
"funcTxt": "G_1226_Sieb",
"ort": "nicht zugewiesen",
"info": "Siebmaschine 1500 UpM / 2 x 4 kW, Doppellagerung / IE4 ",
"options": {
"bremse": true,
"motor_anzahl": "2",
"oldId": "80",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5c7"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Sieb",
"type": "Sieb",
"nr": "1227",
"funcTxt": "G_1227_Sieb",
"ort": "nicht zugewiesen",
"info": "Siebmaschine Fabrikat DS18.42, Umwuchtmotoren 2 x 5.6 kW ",
"options": {
"motor_anzahl": "2",
"oldId": "81",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5ca"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Sieb",
"type": "Sieb",
"nr": "1228",
"funcTxt": "G_1228_Sieb",
"ort": "nicht zugewiesen",
"info": "Siebmaschine MVSI 10/4700-S02, 2 x 3.2 kW, Vibrationsmotor ",
"options": {
"motor_anzahl": "2",
"oldId": "82",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5cd"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Ventil",
"type": "Unbekannt",
"nr": "4221",
"funcTxt": "G_4221_1_Ventil",
"ort": "nicht zugewiesen",
"info": ". ",
"options": {
"oldId": "83",
"oldAggTyp": "Ventil"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5d0"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Pumpe",
"type": "Pumpe",
"nr": "5434",
"funcTxt": "G_5434_Pumpe",
"ort": "nicht zugewiesen",
"info": "Feststoffpumpe",
"options": {
"oldId": "84",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5d3"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Pumpe",
"type": "Pumpe",
"nr": "5421",
"funcTxt": "G_5421_Pumpe",
"ort": "nicht zugewiesen",
"info": "Feststoffpumpe 400V, 50Hz, mit Temperaturfühler Kaltleiter, Moll Motor (FU Elektro-Lieferant, Fabrikat Siemens) 1480 U/min, IE4 ",
"options": {
"fu": true,
"oldId": "85",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5d6"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Pumpe",
"type": "Pumpe",
"nr": "5422",
"funcTxt": "G_5422_Pumpe",
"ort": "nicht zugewiesen",
"info": "Feststoffpumpe 400V, 50Hz, mit Temperaturfühler Kaltleiter, Moll Motor (FU Elektro-Lieferant, Fabrikat Siemens) ",
"options": {
"fu": true,
"oldId": "86",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5d9"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Ventil",
"type": "Unbekannt",
"nr": "1330_1",
"funcTxt": "G_1330_1_Ventil",
"ort": "nicht zugewiesen",
"info": "Elektoventil",
"options": {
"oldId": "87",
"oldAggTyp": "Ventil"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5dc"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Ventil",
"type": "Unbekannt",
"nr": "1330_3",
"funcTxt": "G_1330_3_Ventil",
"ort": "nicht zugewiesen",
"info": "Elektoventil",
"options": {
"oldId": "88",
"oldAggTyp": "Ventil"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5df"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Pumpe",
"type": "Pumpe",
"nr": "5431",
"funcTxt": "G_5431_Pumpe",
"ort": "nicht zugewiesen",
"info": "Feststoffpumpe400V, 50Hz, mit Temperaturfühler Kaltleiter, Moll Motor (FU Elektro-Lieferant, Fabrikat Siemens) 1480 U/min, IE4 ",
"options": {
"fu": true,
"oldId": "89",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5e2"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Pumpe",
"type": "Pumpe",
"nr": "5432",
"funcTxt": "G_5432_Pumpe",
"ort": "nicht zugewiesen",
"info": "Feststoffpumpe 400V, 50Hz, mit Temperaturfühler Kaltleiter, Moll Motor (FU Elektro-Lieferant, Fabrikat Siemens) 1480 U/min, IE4 ",
"options": {
"fu": true,
"oldId": "90",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5e5"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Pumpe",
"type": "Pumpe",
"nr": "5433",
"funcTxt": "G_5433_Pumpe",
"ort": "nicht zugewiesen",
"info": "Feststoffpumpe400V, 50Hz, mit Temperaturfühler Kaltleiter, Moll Motor (FU Elektro-Lieferant, Fabrikat Siemens) 1480 U/min, IE4 ",
"options": {
"fu": true,
"oldId": "91",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5e8"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Ventil",
"type": "Unbekannt",
"nr": "5433_1",
"funcTxt": "G_5433_1_Ventil",
"ort": "nicht zugewiesen",
"info": "Elektroventil",
"options": {
"oldId": "92",
"oldAggTyp": "Ventil"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5eb"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Ventil",
"type": "Unbekannt",
"nr": "5433_2",
"funcTxt": "G_5433_2_Ventil",
"ort": "nicht zugewiesen",
"info": "Elektroventil",
"options": {
"oldId": "93",
"oldAggTyp": "Ventil"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5ee"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Ventil",
"type": "Unbekannt",
"nr": "5433_3",
"funcTxt": "G_5433_3_Ventil",
"ort": "nicht zugewiesen",
"info": "Elektroventil",
"options": {
"oldId": "94",
"oldAggTyp": "Ventil"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5f1"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Pumpe",
"type": "Pumpe",
"nr": "5465",
"funcTxt": "G_5465_Pumpe",
"ort": "nicht zugewiesen",
"info": "Prozesswasserpumpe 400V, 50Hz, Moll Motor 2-polig mit Temperaturfühler Kaltleiter (Stern-Dreieck und Softstart möglich, CAB empfiehlt Softstart) IE4 ",
"options": {
"oldId": "95",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5f4"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Ventil",
"type": "Unbekannt",
"nr": "5465_11",
"funcTxt": "G_5465_11_Ventil",
"ort": "nicht zugewiesen",
"info": "Elektroventil",
"options": {
"oldId": "96",
"oldAggTyp": "Ventil"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5f7"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Pumpe",
"type": "Pumpe",
"nr": "5469",
"funcTxt": "G_5469_Pumpe",
"ort": "nicht zugewiesen",
"info": "Tropfwasserpumpe Angaben durch Max Wild / Pumpe mit eigenständiger Schwimmersteuerung ",
"options": {
"oldId": "97",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5fa"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Kompressor",
"type": "Kompressor",
"nr": "2321_3",
"funcTxt": "G_2321_3_Kompressor",
"ort": "nicht zugewiesen",
"info": "Kompressor (Doppelgurtförderer)",
"options": {
"oldId": "98",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da5fd"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Pumpe",
"type": "Pumpe",
"nr": "5451",
"funcTxt": "G_5451_Pumpe",
"ort": "nicht zugewiesen",
"info": " Ergänzungspumpe Platzwasser",
"options": {
"oldId": "99",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da600"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Pumpe",
"type": "Pumpe",
"nr": "5452",
"funcTxt": "G_5452_Pumpe",
"ort": "nicht zugewiesen",
"info": " Grundwasserbrunnen Ergänzungspumpe Platzwasser",
"options": {
"oldId": "100",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da603"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Bandwaage",
"type": "Waage",
"nr": "2511",
"funcTxt": "G_2511_Bandwaage",
"ort": "nicht zugewiesen",
"info": "Einrollenbandwaage SFB22, Fabrikat WÖHWA, Geschwindigkeitsaufnehmer, inkl. Profinet-Schnittstelle ",
"options": {
"oldId": "201",
"oldAggTyp": "Motor"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da606"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Bandwaage",
"type": "Waage",
"nr": "2525",
"funcTxt": "G_2525_Bandwaage",
"ort": "nicht zugewiesen",
"info": "Förderbandwaage Einrollenbandwaage SFB22, Fabrikat WÖHWA, Geschwindigkeitsaufnehmer, inkl. Profinet-Schnittstelle ",
"options": {
"oldId": "203"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da615"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Silo",
"type": "Fuellstand",
"nr": "4139",
"funcTxt": "G_4139_Silo",
"ort": "nicht zugewiesen",
"info": "Füllstandsmessung Vegapuls C23 ",
"options": {
"oldId": "401",
"oldAggTyp": "Analog"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da618"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Silo",
"type": "Fuellstand",
"nr": "4131",
"funcTxt": "G_4131_Silo",
"ort": "nicht zugewiesen",
"info": "Füllstandsmessung Vegapuls C23 ",
"options": {
"oldId": "402",
"oldAggTyp": "Analog"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da61b"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Silo",
"type": "Fuellstand",
"nr": "4132",
"funcTxt": "G_4132_Silo",
"ort": "nicht zugewiesen",
"info": "Füllstandsmessung Vegapuls C23 ",
"options": {
"oldId": "403",
"oldAggTyp": "Analog"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da61e"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Silo",
"type": "Fuellstand",
"nr": "4133",
"funcTxt": "G_4133_Silo",
"ort": "nicht zugewiesen",
"info": "Füllstandsmessung Vegapuls C23 ",
"options": {
"oldId": "404",
"oldAggTyp": "Analog"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da621"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Silo",
"type": "Fuellstand",
"nr": "4134",
"funcTxt": "G_4134_Silo",
"ort": "nicht zugewiesen",
"info": "Füllstandsmessung Vegapuls C23 ",
"options": {
"oldId": "405",
"oldAggTyp": "Analog"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da624"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Silo",
"type": "Fuellstand",
"nr": "4135",
"funcTxt": "G_4135_Silo",
"ort": "nicht zugewiesen",
"info": "Füllstandsmessung Vegapuls C23 ",
"options": {
"oldId": "406",
"oldAggTyp": "Analog"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da627"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Silo",
"type": "Fuellstand",
"nr": "4136",
"funcTxt": "G_4136_Silo",
"ort": "nicht zugewiesen",
"info": "Füllstandsmessung Vegapuls C23 ",
"options": {
"oldId": "407",
"oldAggTyp": "Analog"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da62a"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Silo",
"type": "Fuellstand",
"nr": "4137",
"funcTxt": "G_4137_Silo",
"ort": "nicht zugewiesen",
"info": "Füllstandsmessung Vegapuls C23 ",
"options": {
"oldId": "408",
"oldAggTyp": "Analog"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da62d"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Silo",
"type": "Fuellstand",
"nr": "4138",
"funcTxt": "G_4138_Silo",
"ort": "nicht zugewiesen",
"info": "Füllstandsmessung Vegapuls C23 ",
"options": {
"oldId": "409",
"oldAggTyp": "Analog"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da648"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Pumpensumpf",
"type": "Behaelter",
"nr": "4222",
"funcTxt": "G_4222_Pumpensumpf",
"ort": "nicht zugewiesen",
"info": ". ",
"options": {
"oldId": "601"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da64b"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Pumpensumpf",
"type": "Behaelter",
"nr": "4223",
"funcTxt": "G_4223_Pumpensumpf",
"ort": "nicht zugewiesen",
"info": ". ",
"options": {
"oldId": "602"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da64e"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Pumpensumpf",
"type": "Behaelter",
"nr": "4227",
"funcTxt": "G_4227_Pumpensumpf",
"ort": "nicht zugewiesen",
"info": ". ",
"options": {
"oldId": "603"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da651"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Zyklon",
"type": "Zyklon",
"nr": "1421",
"funcTxt": "G_1421_Zyklon",
"ort": "nicht zugewiesen",
"info": "Hydrozyklon 624 HD-TZ-RE / Beinhaltet keine EL- Installationen ",
"options": {
"oldId": "604"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da654"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Zyklon",
"type": "Zyklon",
"nr": "1421_1",
"funcTxt": "G_14211_Zyklon",
"ort": "nicht zugewiesen",
"info": "Hydrozyklon 624 HD-TZ-RE / Beinhaltet keine EL- Installationen ",
"options": {
"oldId": "605"
},
"__v": 0,
"displayName": ""
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da657"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Zyklon",
"type": "Zyklon",
"nr": "1422",
"funcTxt": "G_1422_Zyklon",
"ort": "nicht zugewiesen",
"info": "Hydrozyklon 518 HD-TZ-RE / Beinhaltet keine EL- Installationen ",
"options": {
"oldId": "606"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da65a"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Unterbrechertopf",
"type": "Behaelter",
"nr": "1330",
"funcTxt": "G_1330_Unterbrechertopf",
"ort": "nicht zugewiesen",
"info": "Beinhaltet keine EL- Installationen ",
"options": {
"oldId": "607"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da660"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Kettenzug1",
"type": "Unbekannt",
"nr": "5521",
"funcTxt": "G_5521_Kettenzug1",
"ort": "nicht zugewiesen",
"info": "Elektrokettenzug (Hub, Fahren) Typ GM 8 2000.8-1 3kW Hubleistung / Typ EF22 0.25kW Fahrleistung ",
"options": {
"oldId": "701"
},
"__v": 0
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da663"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Nass_Allg",
"type": "Unbekannt",
"nr": "1000",
"funcTxt": "G_1000_Allgmein",
"ort": "nicht zugewiesen",
"info": "Allgemein Nass",
"options": {
"oldId": "1000",
"oldAggTyp": "unbekannt"
},
"__v": 0,
"displayName": ""
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da666"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Wasser_Allg",
"type": "Unbekannt",
"nr": "1001",
"funcTxt": "G_1001_AllgmeinNassaufgabe",
"ort": "nicht zugewiesen",
"info": "Allgemein Wasserhaushalt",
"options": {
"oldId": "1001"
},
"__v": 0,
"displayName": "Allgemein Wasserhaushalt"
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da669"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "ET0_Allg",
"type": "Unbekannt",
"nr": "1002",
"funcTxt": "G_1002_Klaeranlage",
"ort": "Ebene 0",
"info": "ET-Station 0",
"options": {
"oldId": "1002"
},
"__v": 0,
"displayName": "ET-Station 0"
},
{
"_id": {
"$oid": "6996ec897d8011b2d05da66c"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "ET2_Allg",
"type": "Ebene 2",
"nr": "1004",
"funcTxt": "G_1003_Klaeranlage",
"ort": "nicht zugewiesen",
"info": "ET-Station 2",
"options": {
"oldId": "1004"
},
"__v": 0,
"displayName": "ET-Station 2"
},
{
"_id": {
"$oid": "69f20c7aa7354b3110184059"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Pumpensumpf",
"type": "Behaelter",
"nr": "4221",
"funcTxt": "G_4221_Pumpensumpf",
"ort": "nicht zugewiesen",
"info": ". "
},
{
"_id": {
"$oid": "69f86983b611b17c0fd176ca"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Allg_Nassxx",
"type": "Allgemein",
"nr": "1000",
"displayName": "Allgemein Nassbereich",
"ort": "SC Nass",
"info": "Allgemein",
"__v": 0
},
{
"_id": {
"$oid": "69f988fdb4e3c6486058ad1a"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "ET3_Allg",
"type": "Allgemein",
"nr": "1005",
"displayName": "ET-Station 3",
"ort": "Ebene 3",
"info": "ET-Station 3",
"__v": 0
},
{
"_id": {
"$oid": "69f98938b4e3c6486058ad1f"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "ET_HT_Allg",
"type": "Allgemein",
"nr": "1010",
"displayName": "Haustechnick",
"ort": "Schaltschrank",
"info": "ET-Station Haustechnik",
"__v": 0
},
{
"_id": {
"$oid": "69f98973b4e3c6486058ad24"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Aufgabe_Allg",
"type": "Allgemein",
"nr": "1020",
"displayName": "Allgemein Aufgabe",
"ort": "Aufgabe",
"info": "ET-Station Aufgabe",
"__v": 0
},
{
"_id": {
"$oid": "69f989b6b4e3c6486058ad29"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Bel",
"type": "Belechtung",
"nr": "1050",
"displayName": "Beleuchtung",
"ort": "Haustechnik",
"info": "Beleuchtung",
"__v": 0
},
{
"_id": {
"$oid": "69f993a3b4e3c6486058afa9"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "unbekannt",
"type": "unbekannt",
"nr": "0",
"displayName": "unbekannt",
"ort": "unbekannt",
"info": "unbekannt",
"__v": 0
},
{
"_id": {
"$oid": "69f99c5cb4e3c6486058afdd"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "Klaer",
"type": "Klaeranlage",
"nr": "1060",
"displayName": "Klaeranlage",
"ort": "Kläranlage",
"info": "Klaeranlage Kontaktaustausch",
"__v": 0
},
{
"_id": {
"$oid": "69f9bf0eb4e3c6486058b179"
},
"anlageId": {
"$oid": "6995c44ebb286cf2c27da0d8"
},
"name": "WasserInput",
"type": "Einlass",
"nr": "20000",
"displayName": "Wasserabgänge für Visu",
"ort": "Wasser",
"info": "Wasserabgänge für Visu",
"__v": 0
},
{
"_id": {
"$oid": "6a8449cf7b8dac185c1afeec"
},
"anlageId": {
"$oid": "6995c490bb286cf2c27da0da"
},
"name": "H_Verteiler",
"type": "Band",
"nr": "100",
"displayName": "Gruppe Band 100",
"ort": "BA3",
"info": "100",
"__v": 0
},
{
"_id": {
"$oid": "6a844a387b8dac185c1afeed"
},
"anlageId": {
"$oid": "6995c490bb286cf2c27da0da"
},
"name": "H_verteiler2",
"type": "Band",
"nr": "101",
"displayName": "VerteilbandHinten",
"ort": "BA3",
"info": "Hinten",
"__v": 0
}]